Services

image1

Galt Engineering has design experience (both ANSI and IEC) with:

 

  • Overhead and underground distribution systems
  • Utility scale solar collector systems
  • Backup generators (Diesel, steam, gas turbine)
  • Control house design (switchgear/panels, batteries/chargers, and annunciator panels)
  • Critical service, automatic transfer and back-up systems
  • Fuel system design (piping, pumping, separators, filters and tanks)
  • One-line, three-line, schematics, wiring diagrams, and connection diagrams
  • Site, grading, grounding, foundation, retention, landscaping, and lighting drawings
  • Commissioning and training
  • Switchgear and control panel schematics and wiring diagrams
  • Duct bank, ground grid and oil containment design
  • Site and equipment layout and plan drawings
  • Protection and monitoring modernization
  • Start-up services
  • Substations (site, structural, bus, grounding, lighting, and equipment)

image2

Galt Engineering can provide these types of studies and services:

 

  • SEL relay and communications device programming
  • Overcurrent protection (including fault analysis and arc-flash)
  • Equipment coordination (physical and electrical; power, relaying, control, metering)
  • Equipment retrofitting (protective devices and monitoring devices)
  • Equipment start-up and commissioning
  • Failure analysis (system level through individual components)
  • Final documentation preparation and training (operating procedures,
  • Power factor correction studies
  • Integrate operating procedures (normal, maintenance, and emergency)
  • Overvoltage protection (including margin of protection calculations)
  • Peer review
  • Power cable ampacity (duct banks, short circuit)
  • Protective device coordination
  • Short-term and long-range system planning
  • Specification development (equipment and construction)
  • Substation grounding (rating, step, and touch)
  • System analysis (power flow, voltage drop, capacity, sectionalizing, and restoration)
  • System integration (medium voltage)

image3

Galt Engineering has experience with (both ANSI and IEC) equipment:

 

  • Switching (load break and dead break in oil, SF6, and air)
  • Primary load Interrupters (vacuum, oil, air, Manual, mechanically, and electronically controlled)
  • Cable and conduit systems (direct buried, wire tray, and long pulls. Power, URD, and PILC)
  • Fusing (Medium Voltage, Current Limiting, Expulsion, Electronic and Under Oil)
  • Connectors (200A Loadbreak, 900A Deadbreak, Compression, and Load Tension)
  • Transformers (Substation, Bulk Power, and Distribution, through 10MVA and 138kV)
  • Secondary Unit Substations (dry and cast coil transformers)
  • Power Switchboards (Fixed molded case, fused and circuit breakers)
  • Switchgear (Metal Clad, Metal Enclosed, Pad and vault mounted, SF6, vacuum, oil, air, solid)
  • Dielectrics (Air, oil, epoxy, EPDM and silicone rubber, plastic, SF6, porcelain, and paper)
  • Surge Arresters (Series Capacitor Protectors, Station, distribution, LV. Polymer and porcelain)
  • Reclosers (Vacuum, Oil, Hydraulic, Electronic, digital controls, and communication)

Galt Engineering can serve these clients and these markets:

image4

  • Mission Critical Facilities Owners, Engineering Design Firms, or Electrical Contractors


  • Also, Attorneys, Building Owners, Commercial, Consultants, Contractors, Distributors, Electric Utilities, General Contractors, EPC's, Independent Power Producers, Independent System Operators, Industrial, Investor Owned Utility, Legal, Manufacturers, Manufacturers Reps, Municipal Utility, Power Producers, Renewable, Researchers, Sales Agents, Solar, State Owned Facilities, Test Labs, Wholesaler, Wind